|
|
 |
D-link DSN-2100-10 XSTACK STORAGE 4X1GBE ISCSI SAN ARRAY 8BAYS 2U
W/O DRIVES |
|
|
 |
Product Features |
 |
|
| Product ID |
30041 |
| Brand |
D-link |
| Vendor Code | DSN-2100-10 |
| Description |
DSN-2100-10 > 4x1GbE iSCSI SAN Array, 8 Bays, 2U, w/o Drives, with Trays
D-Link DSN-2100-10 xStack Storage 4x1GbE iSCSI SAN Array, 8 Bays, 2U, w/o
Drives, with Trays
Product Features:
• Integrated iSCSI System-on-a-Chip (SoC) Solution that can Handle over 80,000
I/Os per Second
• Four 1GbE Ports
• 8TB Capacity with 1TB Hard Drives (Supports Higher Capacity Drives as They Are
Introduced)
• Embedded Disk Controller Supporting RAID Levels 0, 1, 1+0, and 5
Overview
Product Description:
The D-Link DSN-2100-10 xStack Storage Area Network (SAN) Array is designed to
provide a smaller, more value oriented solution for entry-level and SMB
customers. The heart of the DSN-2100-10 SAN Array is based on the same powerful
System-on-a-Chip (SoC) design found in larger arrays such as the DSN-3000 series
of products, but housed in a smaller chassis. Utilizing a 10Gbit iSCSI SoC
solution that can handle over 80,000 I/Os per second and capable of supporting
8TBs of raw capacity using 1TB hard drives (and even higher capacity hard drives
as they are introduced), the DSN-2100-10 SAN Array can easily be implemented as
nearline storage or as a supplement to your primary backup and recovery device.
This evolutionary advancement in performance is a testament to the tightly
integrated xStack Storage architecture and is a sharp contrast to the discrete
implementation of competing products.
iSCSI for IP Networks
SAN has been traditionally reserved for Fibre Channel networks until the recent
introduction of iSCSI that extends this powerful yet simple centralized backend
storage system to IP networks. By utilizing existing Ethernet technology, the
cost associated with separate host bus adapters and the per-Gigabyte cost for
storage is significantly reduced. iSCSI SANs can leverage the Ethernet
infrastructure and standards which are quite familiar to your IT staff.
Check out the product video in D-LinkTV
Four 1GbE Interfaces
The DSN-2100-10 SAN Array implements four 1GbE ports and supports IEEE 802.3ad
Link Aggregation Groups (LAG) for full offload capability so that all four ports
can be grouped together, totaling up to 425MB/s bandwidth, for increased
throughput and redundancy.
Click to enlarge
System-on-a-Chip (SoC) Implementation
By utilizing a SoC design, the DSN-2100-10 SAN Array combines both networking
and storage functions into a single specialized Application Specific Integrated
Circuit (ASIC). The SoC solution combines 10Gbps iSCSI, TCP & IP offload,
embedded processors, and storage virtualization firmware onto a single chip. The
tight integration of these functions eliminate interoperability, timing, and
support issues found in competitive products that offer “discrete
implementation” wherein a chassis, a main motherboard, a RAID storage
controller, iSCSI software or controller, network interface cards, and operating
system software are chosen separately and then assembled. The DSN-2100-10 SAN
Array outperforms these discrete implementations and does so at a lower price
point. It also delivers mission critical data quickly with state-of-the-art
reliability.
RAID for Efficiency
The DSN-2100-10 SAN Array platform features 8 hot swappable Serial ATA (SATA)
disk drive bays supporting 8TB raw capacity using 1TB hard drives (and even
higher capacity hard drives as they are introduced) in RAID level 0, 1, 1+0 and
5 configurations. You can quickly deploy a SAN using inexpensive SATA disk
drives and, depending on your growing storage needs, you can simply add more
drives as you go.
Recommended hard drives for the DSN-2000 series SAN arrays:
To see a list of compatible drives, please see our Interoperability Matrix
documentation (PDF).
Embedded Centralized Storage Management
The embedded user-friendly IP-SAN Device Manager (IDM) provides comprehensive
storage network management. Boasting a rich set of management features, this
suite of utilities allow monitoring and control of your SAN via the SMI-S
(Storage Management Initiative Specification) command set. Combined with an
embedded secure server, users will be able to remotely configure and monitor
their SAN storage subsystems.
Advanced Management Features
The DSN-2100-10 SAN Array provides additional advanced features for efficient
management of network storage and optimal performance.
Cache Management: Provides adaptive and persistent cache management. This
provides write-back, write-through, write coalescing, and multi-stream
read-ahead on a volume basis. This optimizes cache utilization and performance
in an application dependent manner.
VLAN Zoning: Supports IEEE 802.1q VLAN tagging to segregate traffic into
isolated zones for secure access and jumbo frames to improve the network
throughput and reduce CPU overhead.
Volume Virtualization: The DSN-2100-10 has storage management software that
provides volume virtualization features by utilizing the concept of storage
Extents. Extents are the fundamental building blocks used to enable features
such as RAID, online capacity expansion and volume migration. Drives of
disimilar size can be used to create volumes. Growth can occur without volume
migration or reconstruction. Single drives can contain multiple and divergent
RAID technologies. Volume structure can also provide infrastructure for Snapshot
copies.
RAID Support: RAID Levels 0, 1, 1+0 and 5 (striped sets, mirrored sets, striped
mirrored sets, and parity sets) are supported, allowing different storage
options.
Online Capacity Expansion and RAID Level Migration:: Volumes can be expanded
and/or migrated to other RAID levels while online and with minimal impact on
users. For example, a mirror volume of two drives can easily be converted to a
parity volume of three or more drives while users continue to access this
storage.
Micro Rebuilds: Provides protection against unresponsive SATA commands by
forcing a response within a preset time limit.
An iSSCSI array can prove to be a valuable tool to supplement your network
storage foundation. Whether providing a low- cost block-based solution for data
backup and recovery, replacement of Direct-Attached Storage (DAS) drives, or
providing a cost-effective entry-level nearline storage solution, the
DSN-2100-10 xStack Storage Area Network (SAN) Array can meet your immediate
needs.
Product Specs
Technical Specifications
Drive Bays
• 8
Drive Interface Support
• SATA-II support
System Memory
• 256MB to 512MB (512MB standard)
Cache Memory
• 256MB to 4GB (512MB standard)
Battery Backup for Cache
• Standard (approximately 72 hours on full charge)
Bandwidth
• Up to 425MB/s
Storage Capacity
• 8TB capacity with 1TB hard drives (supports for higher capacity drives as they
are introduced)
Operating Systems Supported
• Windows® Vista® 32-bit & x64 (Ultimate & Enterprise) with Built-in iSCSI
initiator
• Windows Server 2003® 32-bit & x64 SP1 (Standard & Enterprise) with v2.04 iSCSI
initiator
• Windows Server 2003 R2 32-bit & x64 (Standard & Enterprise) with v2.04 iSCSI
initiator
• Windows XP Pro 32-bit & x64 with v2.04 iSCSI initiator
• Windows 2000 Advanced Server with v1.6 & v2.01 iSCSI initiator
• Fedora® Core® 6 & 7
• Red Hat® 7.3
• Red Hat 9
• Red Hat Enterprise® WS 3 update 4
• Red Hat Enterprise ES 4 update 4 & 5 32-bit & x64
• Red Hat Enterprise AS update 4
• SuSE® Professional 9.3 32-bit & x64
• OS® X (10.4.7 | 10.4.8 | 10.4.10)with Intel® and Power PC CPUs
Supported NICs, iSCSI Accelerators and iSCSI HBAs
• Intel® Pro 1000MT & XT [1GbE]
• Intel Pro 10000 CX4 [10GbE]
• Chelsio® S210X-SR-XFP (S2iO) [10GbE]
• Neterion® Xframe® II & Xframe E [10GbE]
• Alacritech® SES2104ET (drivers: SNP 9.1.0.1092 & 7.3.1.0)
• Alacritech SES2102ET (drivers: SNP 9.1.0.1092 & 7.3.1.0)
• QLogic® 4010C
• QLogic 4052C
iSCSI Network Interface
iSCSI Network Interface
• Four (4) 1GbE Copper Ports
Host Interface
• iSCSI Draft 20 compliant initiator
Connections
• 1,024 hosts
CHAP Authentication
• Yes
Access Control of Management
• Yes
iSCSI/TCP/IP Full HW Offload
• Yes
Jumbo Frames Support
• Yes
LAG Support (Link Aggregation)
• Yes – Up to four (4) LAGs (IEEE802.3ad Link Aggregation Group)
VLAN Support
• Up to eight (8). 1-to-1 mapping between IP subnet and VLAN. Multiple VLANs per
physical port with VLAN tag. All physical ports in LAG belong to same VLAN
(IEEE802.1Q Tag)
Volume & RAID Support
RAID Controller
• Single- Integrated in ASIC
RAID Support
• RAID Levels 0, 1, 1+0 and 5
Volumes
• 1,024 Virtual Volumes (256 accessible per initiator)
Target Nodes
• 1,024
Online Capacity Expansion
• Yes
Hot Swappable Drives
• Yes
Instant Volume Access
• Yes
Free Space Defragmentation
• Yes
Auto-Detection Failed Drive
• Yes
Auto-Rebuild Spare Drive
• Yes
RAID Level Migration
• Yes
Drive Roaming in Power Off
(configured drives are not bay-specific)
• Yes
Micro Rebuilds
• Yes
Storage Management
Embedded IP-Based Management GUI
• Create, manage, expand and monitor storage pool, volumes and RAID
• Event manager to view and persist events
Firmware Field Upgradeable
• Yes
SMI-S Version 1.1
• Yes
Power
Supply Type
• Redundant 2U 400 Watt
Input Voltage
• 100-240 VAC
Input Frequency
• 47-63 Hz
Input Current
• 8A Maximum at 100VAC and 4A Maximum at 240VAC
(maximum amps vs. voltage varies linearly throughout this voltage range)
Power Factor Correction
• 95%@110V, Full load
Power Consumption
• 360W (full configuration)
Thermal
• 1260 BTU / hour (full configuration)
Environmental
Operating Temperature
• 32° to 104°F (0° to 40°C)
Storage Temperature
• -4° to 158°F (-20° to 70°C)
Operating Humidity
• 20% ~ 90% (Non-condensing)
Storage Humidity
• 10% ~ 95% (Non-condensing)
Physical (approximate)
Form Factor
• 2U industry-standard 19-inch rack
Dimesnsions (D x W x H)
• 25in x 17.25in x 3.5in (63.5cm x 43.8cm x 8.9cm)
18.75in (47.6cm) wide at the mounting brackets
Weight
• 45 lbs / 20.4 Kg (full configuration)
International Approvals
Emissions
• CE Class A, FCC Class A, C-Tick Class A, VCCI Class A
Safety
• CSA 60950-1, UL60950-1, IEC 60950-1, EN 60950-1
Warranty and Support
Warranty
• 2-Year Limited* (manufacturer’s warranty on hard drives)
Extended Warranty
• Available
Support
• 1 year, 9 hours per day / 5 days per week Technical Support
Available Configurations
DSN-2100-10
• xStack 4x1GbE iSCSI SAN Array, 8 Bays, 2U, w/o Drives, with Trays
|
| Warranty | 1 Year Manufacturer's return to base | | Link | D-link DSN-2100-10 XSTACK STORAGE 4X1GBE ISCSI SAN ARRAY 8BAYS 2U |
| Product image and
description may vary due to insufficient information from vendor. Please base
you purchase decision on the product title and vendor code. |
|
 |
Other customers who bought this also bought |
 |
|
 |
Thermaltake Kandalf Silver Aluminium Case with Window No Power Supply CASE-VA9000SWANP |
 |
Inno3D Geforce 9400GT PCIE 512MB 128bit DDR2, 460/ 667MHz, Dual-Link DVI, VGA, HDTV, Fan |
 |
Canon 1000DB EOS 1000D Body Only 10.1mp CMOS, DiG!C III, 7-pt AF, 3.0fps 1000DB |
 |
Shuttle SN78SH7 AMD AM2, nForce 8200, VGA, PCIE, PCI, GLAN, HD7.1 Audio, |
|
|
 |
|