Apc Netshelter Sx 48u Rack 600m W X 1200m D Enclosure With Roof Sides, Black Ar3307
OVERVIEW
NETSHELTER® SX
Feature-rich rack enclosure optimized for easy installation, managing cables,
integrating power distribution, and maximizing airflow.
World's most versatile rack enclosure
The NetShelter SX is a multi-functional rack enclosure influenced by customer
feedback from around the world. These enclosures are designed to meet current IT
market trends and applications ranging from high density computing and
networking to broadcast and audio-video. With a strong focus on cooling, power
distribution, cable management and environmental monitoring, the NetShelter SX
rack enclosure provides a reliable rack-mounting environment for
mission-critical equipment.
FEATURES
NETSHELTER SX FEATURES & BENEFITS
Integrated with InfraStruxure products
Schneider Electric cooling, power distribution, and cable management products
work seamlessly with IT enclosures to provide a complete infrastructure support
system.
Schneider Electric Rack Systems Compatible
Compatible with a variety of Schneider Electric rack accessory products to
provide the ability to create a complete rack system. Configure rack solutions
using industry leading Schneider Electric Design Portal - Small IT Solution
Designer configurator complete with verification of product compatibility and
useful 3rd party equipment catalog to aid in visualizing your ideal rack
solution.
Optimized for high capacity cable management systems
NetShelter SX enclosures are optimized for use with high capacity cable
management systems that attach to equipment mounting rails inside enclosures
aligning with equipment mounting u-spaces and provide channels for routing and
managing cabling.
Vendor-neutral EIA-310 19in Rack Mounting Compatibility Guaranteed
Vendor-neutral mounting for guaranteed compatibility with all EIA-310 compliant
19" equipment. The "Fits Like a Glove" money back guarantee provides peace of
mind that all of your EIA-310-E compliant rack-mount equipment will physically
fit in a NetShelter.
CONVENIENCE
Cable access openings with pre-installed brushes
Large cable access slots in the roof provides access for overhead cable egress.
The bottom design allows for unobstructed cable access through a raised floor.
Roof includes openings with brush strips pre-installed in locations biased
towards the front of the enclosure to allow for data cable passthrough and
provisions for air containment.
Simple Selection
No need to spend hours choosing from and compiling dozens of part numbers to
create a single enclosure. Schneider Electric has made it easy by handling the
details and providing complete enclosures with single part numbers.
Perforated front door with curved profile
Perforated front and rear doors provide ample ventilation for servers and
networking equipment. Front door perforated area is optimized with a curved
profile to provide greater surface area and allowance of more perforation
coverage and higher perforation rating.
Quick release doors
Front door can be moved to the opposite side or interchanged with rear doors.
Doors are easily removed with simple lift-off design.
Half-height side panels and option with brush strips for pass-through
Half-height quick release side panels reduce size and weight for easy handling
and access to equipment. Side panels are lockable utilizing a single key with
the doors. Now available are side panel options integrated with pass-through
holes and brush strips for routing cabling to adjacent racks in a row while
still maintaining proper airfow.
Easily removable cable access roof
Roof can be removed with simple pull-pin hinges for access during equipment
installation or even with cabling already in place and routed through the cable
openings. Once removed the roof is reversible to reposition the larger cable
openings for power distribution plugs and connectors.
Eyebolt support integrated into enclosure frame
Integrated eyebolt holes at the top of the enclosure frame allow the enclosure
to be lifted for movement and enclosure placement using eyebolt lifting
mechanisms. Refer to enclosure user documentation for detailed specifications on
eyebolt requirements and enclosure weight limits.
Equipment mounting rails integrate with patch cabling systems
Equipment mounting rails include zero U mounting holes beside the EIA 19"
mounting space that allow the installation of Data Distribution Cable (DDC)
patch systems without taking up any critical equipment U-space. AV and
Networking enclosure designs do not include hole locations for integration of
DDC cabling. Other 1U, 2U, and rear enclosure zero U options are available for
use with these enclosures.
Enclosure adjustment tools and hardware provided
All enclosures are provided standard with hardware bag that includes hardware
for mounting IT equipment and tools for simple enclosure adjustment.
AGILITY
Pre-installed full-enclosure height rear accessory channels
Integrated and adjustable rear accessory channel provides zero U mounting
locations for toolless accessories. Each channel has two mounting bays to
support a combination of up to four accessories such as PDUs and vertical cable
organizers. 1070mm (42in), 825mm (32 in), and deep enclosures and networking
enclosures include two channels. 1200mm (48in) deep enclosures include four
channels. Channels are pre-installed at the factory in the rear of the enclosure
but can be moved to other locations of the enclosure along the side brace to
resituate cable management where it is needed most.
Adjustable mounting rails with captive hardware and rapid alignment
The vertical mounting rails can be adjusted in 1/4 in (6.4 mm) increments
covering virtually any mounting requirement for IT equipment. Easy alignment
feature integrated into the enclosure mounting rail and side brace for quick
alignment verification without the use of tools to verify alignment. U positions
are numbered front and back for rapid installation of equipment.
Split rear doors
Split rear doors improve access and serviceability to rear of rack mounted
equipment. The split rear doors help to maximize floor space. Only 11 inches
(279 mm) of clearance is required behind the enclosures to allow for door swing.
Low-profile castors and adjustable leveling feet from underneath or above
Enclosures are shipped standard with both leveling feet and castors. Leveling
feet can be quickly adjusted through the use of a screwdriver or drill,
eliminating the need to reach underneath with a wrench.
Integrated joining hardware with multiple width enclosure alignment
Enclosures include pre-installed joining hardware to join enclosures in a row
and provide additional stability to the enclosure. The pre-installed joining
hardware includes holes for joining to an adjacent enclosure at 600mm centers or
24in centers depending upon the floor layout.
Special packaging options for shipping rack with equipment mounted
Enclosures with shock packaging are standard enclosures with provisions in the
packaging design and enclosure assembly for shipping the enclosures with
equipment mounted inside. Check apc.com for enclosure size options and
availability.
Enclosure assemble-to-order (ATO) options capable
The Enclosure ATO (Assemble-to-Order) options provide a level of customization
for enclosure customers beyond the standard enclosure models. This customization
is limited to the assembly of the enclosure itself and does not include
additional enclosure mounted components. For example, the enclosure can be
assembled without sides, doors, or without sides and doors. Check apc.com for
enclosure size options and availability.
SAFETY
Designed for enhanced structural stability
A proven frame design, heavy-gauge mounting rails, and heavy-duty casters
provide for 3000 lb (1364 kg) static (levelling feet) and 2250 lb (1023 kg)
dynamic (castor) load ratings. Enclosures have been tested and approved to be
combined with proper bolt down accessories to meet various seismic requirements.
Check apc.com for product documentation for specific requirements.
Integrated electrical grounding
The roof, side panels and front and rear doors are grounded to the frame of the
enclosure. Eight additional electrical grounding inserts are located on the
frame for external grounding.
Marketing Text | Feature-rich enclosures optimized for easy installation, managing cables, integrating power distribution, and maximizing airflow. |
PI Date | Feb 2011 |
Brand Name | APC |
Manufacturer Web Site | http://www.apc.com |
Product Line | Not defined |
Product Type | Deep Enclosure |
Dynamic Load | 1023Kg |
Rack Height | 48U |
Static Load | 1364Kg |
Depth (mm) | 1200.0 |
Height (mm) | 2258.0 |
Weight (Kg) | 149.6 |
Width (mm) | 600.0 |
Colour | Black |
Other Features | * Vendor-neutral mounting for guaranteed compatibility with all EIA-310 compliant 19 inch equipment. * Overhead cable troughs and partitions install toollessly on the roof of the enclosure eliminating the need for ceiling mounted or underfloor mounted cable trays. * APC cooling, power distribution, and cable management products work seamlessly with the enclosures to provide a complete infrastructure support system. |
Warranty Information | 5 year repair or replace |