QUICK OVERVIEW

Replacement Warranty 2 yr Int. Batteries OL2000ERTXL2U

CyberPower OL2000ERTXL2U is a high-performance UPS featuring online double-conversion topology, which provides seamless pure sine wave power for mission-critical devices such as NAS and servers, DVRs/surveillance systems, transportation and infrastructure, and emergency systems. It’s typically integrated in the back office, server room, and data center environment. The rackmount / tower convertible design gives it enhanced flexibility for installation and operation in almost any environment. By manually setting the UPS to ECO Mode, the UPS automatically detects the input power quality and discerns whether it should operate in Line Mode or ECO Mode. Under poor power conditions, the UPS will run in Line Mode, which guarantees the highest level of protection and the best possible power quality. When the input power quality is acceptable, the UPS switches to ECO Mode, which increases the total output power efficiency by up to 95%.

FEATURES

  • Online (Double Conversion) UPS Topology
  • Energy Saving Technology
  • Generator Compatible
  • Overload Protection
  • Critical/ Non-critical Load Outlets
  • Zero Transfer Time
  • Smart Battery Management (SBM)
  • Hot-swappable Battery Packs
  • External Battery Module (EBM)
  • Surge and Spike Protection
  • EMI and RFI Filtration
  • Phone/ Fax/ Modem/ DSL/ Network Protection
  • LCD Status Display
  • Detachable LCD Panel
  • Emergency Power Off (EPO) Port
  • PowerPanel® Management Software
  • SNMP/ HTTP Remote Management Capability
  • Rack/ Tower Convertible Configurations

TYPICAL APPLICATION

  • Data Closets
  • NAS & Servers
  • Home Theater Systems
  • DVRs/Surveillance Systems
  • POS Systems
  • Transportation & Infrastructure
  • Vehicle/Yacht
  • Emergency Systems
  • Electric Lighting
  • Back Office
  • Server Room
  • Data Center

FEATURE FOCUS

Online (Double Conversion) UPS Topology

Known to provide the highest power protection from disruptive power issues, the online double-conversion topology first goes through AC to DC conversion, and then invert DC into perfect sine wave AC output, guaranteeing the best power quality for even the harshest power conditions at all times while also supporting zero transfer time.

Smart Scheduling

Smart Scheduling is a self-learning energy-saving technology with the ability to analyze the fluctuations of utility power and dynamically find the most suitable operating scheme for your existing power system. It ensures the most savings in energy while maintaining the highest level of protection for your mission-critical devices.

GENERAL

UPS Topology
Online Double Conversion
Energy Saving Technology
Online ECO Mode Efficiency > 93%
Active PFC Compatibility
Yes

INPUT

Generator Compatibility
Yes
Nominal Input Voltage (Vac)
200
208
220
230
240
Input Voltage Range (Vac)
190 ~ 300
Adjustable Voltage Range (Vac)
0~60% Load for 120 ~ 139 Vac
0~70% Load for 140 ~ 159 Vac
0~80% Load for 160 ~ 179 Vac
0~90% Load for 180 ~ 189 Vac
0~100% Load for 190 ~ 300 Vac
Input Frequency (Hz)
50 ± 10
60 ± 10
Input Frequency Detection
Auto-sensing
Rated Input Current (A)
10
Input Power Factor
0.99
Input Connector Type
IEC C14  
Detachable Power Cord Plug Type
IEC C14  
Power Cord Length (ft.)
10
Power Cord Length (m.)
3

OUTPUT

Capacity (VA)
2000
Capacity (Watts)
1800
On Battery Waveform
Pure Sine Wave
On Battery Voltage(s) (Vac)
200 ± 2%
208 ± 2%
220 ± 2%
230 ± 2%
240 ± 2%
Output Voltage Setting
Configurable
On Battery Frequency (Hz)
50 ± 0.5%
60 ± 0.5%
Output Frequency Setting
Configurable
Power Factor
0.9
ECO Mode Voltage Tolerance
± 10 %
± 15 %
Overload Protection
Internal Current Limiting , Circuit Breaker
Overload Protection (Line Mode)
105~125% Load for 1 min, 125~150% Load for 10 sec
Overload Protection (Battery Mode)
105~130% Load for 10 sec, 130~150% Load for 2 sec
Overload Protection (Bypass Mode)
Circuit Breaker
Crest Factor
3 : 1
Harmonic Distortion (Linear Load)
THD<3%
Harmonic Distortion (Non-linear Load)
THD<5%
Internal Bypass
Automatic Bypass , Manual Bypass
Outlet(s) - Total
9
Outlet Type
IEC C13 x 8  
IEC C19 x 1  
Outlet(s) - Battery & Surge Protected
9
Outlet(s) - Critical Load (CL)
5
Outlet(s) - Non-Critical Load (NCL)
4
Typical Transfer Time (ms)
0
 

BATTERY
Runtime at Half Load (min)
18
Runtime at Full Load (min)
6
Typical Recharge Time (Hours)
5
Start On Battery
Yes
Smart Battery Management (SBM)
Yes
User Replaceable
Yes
Hot-Swappable
Yes
Battery Type
Sealed Lead-acid
Replacement Battery Pack
RBP0076
RBP Quantity (pcs)
1
Battery Quantity (Each RBP) (pcs)
6
Battery Voltage (Each RBP) (V)
72
Single Battery Capacity (AH)
12 V 9 AH
Extended Battery Module (EBM)
BPE72V60ART2US
Max. EBM Quantity (pcs)
10
SURGE PROTECTION & FILTERING
Surge Suppression (Joules)
1335
EMI/RFI Filtration
Yes
Phone/Network Protection RJ11/RJ45 (Combo)
1-in, 1-out
MANAGEMENT & COMMUNICATIONS
LCD Panel
Yes
Detachable LCD Panel
Yes
LCD Information Display
Operation Type , Power Status , Battery Status , Load Status , Fault & Warning , Other Information ,Event & Log
LCD Setting & Control
Mode Setting , Alarm Setting , Input & Output , Battery Setting , Fault & Warning , Communication ,Event & Log , Security Setting , Language
LED Indicators
Power On , Line Mode , Battery Mode , Bypass Mode , Battery Capacity , Low Battery , Overload , UPS Fault , Wiring Fault , Replace Battery
HID Compliant USB Port(s)
1
Serial Port
Combo (RS232 + Dry Contact)
Dry Contact (with Relay)
Yes
Emergency Power Off (EPO) Port
Yes
Audible Alarms
Battery Mode , Low Battery , Overload , Overcharge , Overheat , UPS Fault , Replace Battery
Power Management Software
PowerPanel® Business Edition
SNMP / HTTP Remote Monitoring
Yes - with optional RMCARD205
PHYSICAL
Form Factor
Rack/Tower
Enclosure Construction
Metal
Color
Black
Rackmount Rail
Yes
Rackmount Ears
Yes
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
17 x 3.5 x 34.6
Dimensions (WxHxD) (mm.)
433 x 88 x 600
Weight (lbs.)
68.2
Weight (kg.)
31
Installed Rack Height (U)
2
SHIPPING DIMENSIONS
Dimensions (WxHxD) (in.)
22.2 x 9.4 x 34.6
Dimensions (WxHxD) (mm.)
565 x 240 x 880
Weight (lbs.)
86.9
Weight (kg.)
39.5
ENVIRONMENTAL
Operating Temperature (°F)
32 ~ 104
Operating Temperature (°C)
0 ~ 40
Operating Relative Humidity (Non-condensing) (%)
0 ~ 90
Operating Elevation (feet/meters)
0-10,000 feet (0-3,000 meters)
Storage Temperature (°F)
5 ~ 113
Storage Temperature (°C)
-15 ~ 45
Storage Relative Humidity (Non-condensing) (%)
0 ~ 95
Storage Elevation (feet/meters)
0-50,000 feet (0-15,000 meters)
Online Thermal Dissipation (BTU/hr)
759
Audible Noise at 1.5M from Surface of Unit (dBA)
55
CERTIFICATIONS
Certifications
CE , BSMI , C-Tick
RoHS
Yes
WARRANTY
Product Warranty Period (Year)2
Battery Warranty Period (Year)
2

*Capacity (VA/Watts): 2000VA/1800W
*Typology: Online(Double Conversion)
*Form Factor:Rackmount/Tower (Convertible)
*Energy-Saving Technology: Yes
--Input:
*Voltage Range:
120~139Vac for 0~25% Load
140~159Vac for 0~50% Load
160~179Vac for 0~75% Load
180~280Vac for 0~100% Load
*Frequency Range: 40~70 Hz
*Input Plug Type: IEC C14
--Output:
*Voltage Range:Pure Sinewave at 200,208,220,230,240Vac (Configurable)±2%
*Frequency Range: 50/60Hz(Auto-Sensing or Configurable) ±0.25Hz
*Transfer Time (Typical): 0ms
*Overload Protection:
Line Mode: 105~125% Load for1 min, 126~150% Load for 10 sec
Battery Mode: 105~130%
*Lightening/Surge Protection:Yes
*DSL/Phone/Fax/Modem protection: RJ11/RJ45(One In/One Out)
*Dimensions(H x W x D)(mm): 88x433x600
*Weight(kg):31
*Sealed Maintenance Free Lead Acid Battery:12V 9AH x6
*Hot-Swappable: Yes
*Typical Recharge Time: 4 Hrs
*Half-load / Full-load (mins):17/6
*Indicators:Power On, Line Mode, Battery Mode, Bypass Mode, Fault, Replace Battery
*Audible Alarms: Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery
*Multi-Function LCD Readout: Yes
*PowerPanel® Business Edition
*Self Test: Yes
*Auto-Charge: Yes
*Auto-Restart: Yes
*Auto-Overload Recovery: Yes
*COM Interface: (1) Serial Port (RS232), (1) USB Port, (1) Relay Out, (1)EPO
*Cold Start(D): Yes