Cyberpower Online Series 6000va/ 5400w Rack/ Tower Online Ups - (ol6000ert3up)-2 Years Adv. Replacement

SKU
252995
Brand
Warranty
1 Year Manufacturer's return to base

No Longer Available

$0.00
Buy Now And Earn 0 Reward Points!

QUICK OVERVIEW

Warranty incl. 2 yr Int. Battery OL6000ERT3UP

CyberPower OL6000ERT3UP is a high-performance UPS featuring online double-conversion topology, which provides seamless pure sine wave power for mission-critical devices such as NAS and servers, DVRs/surveillance systems, transportation and infrastructure, and emergency systems. It’s typically integrated in the back office, server room, and data center environment. The rackmount / tower convertible design gives it enhanced flexibility for installation and operation in almost any environment. By manually setting the UPS to ECO Mode, the UPS automatically detects the input power quality and discerns whether it should operate in Line Mode or ECO Mode. Under poor power conditions, the UPS will run in Line Mode, which guarantees the highest level of protection and the best possible power quality. When the input power quality is acceptable, the UPS switches to ECO Mode, which increases the total output power efficiency by up to 95%.

FEATURES

  • Online (Double Conversion) UPS Topology
  • Energy Saving Technology
  • Generator Compatible
  • Backfeed Protection Connector
  • Overload Protection
  • Maintenance Bypass Switch
  • Critical/ Non-critical Load Outlets
  • Zero Transfer Time
  • Smart Battery Management (SBM)
  • Hot-swappable Batteries
  • Extended Battery Module (EBM)
  • Surge and Spike Protection
  • EMI and RFI Filtration
  • Phone/ Fax/ Modem/ DSL/ Network Protection
  • LCD Status Display
  • Detachable LCD Panel
  • Emergency Power Off (EPO) Port
  • PowerPanel® Management Software
  • SNMP/ HTTP Remote Management Capability
  • Rack/ Tower Convertible Configurations

TYPICAL APPLICATION

  • Data Closets
  • NAS & Servers
  • Home Theater Systems
  • DVRs/Surveillance Systems
  • POS Systems
  • Transportation & Infrastructure
  • Vehicle/Yacht
  • Emergency Systems
  • Electric Lighting
  • Back Office
  • Server Room
  • Data Center

FEATURE FOCUS

Online (Double Conversion) UPS Topology

Known to provide the highest power protection from disruptive power issues, the online double-conversion topology first goes through AC to DC conversion, and then invert DC into perfect sine wave AC output, guaranteeing the best power quality for even the harshest power conditions at all times while also supporting zero transfer time.

Manual Bypass Switch

Within power-hungry, high-density data centers, power continuity is a must. In order to allow service personnel to carry out fast on-site maintenance without having to shut down any connected equipment, the manual bypass switch plays the main role to help safely transfer the supply power from UPS to the utility.

GENERAL UPS Topology
Online Double Conversion
Energy Saving Technology
Online ECO Mode Efficiency > 95%
Energy Star Qualified
Yes
Active PFC Compatibility
Yes
INPUT Generator Compatibility
Yes
Nominal Input Voltage (Vac)
200
208
220
230
240
Input Voltage Range (Vac)
180 ~ 280
Adjustable Voltage Range (Vac)
0~25% Load for 120 ~ 280 Vac
0~50% Load for 140 ~ 280 Vac
0~75% Load for 160 ~ 280 Vac
0~100% Load for 180 ~ 280 Vac
Input Frequency (Hz)
50 ± 10
60 ± 10
Input Frequency Detection
Auto-sensing
Rated Input Current (A)
30
Input Power Factor
0.99
Backfeed Protection Connector
Yes
Input Connector Type
Hardwire Terminal Block
OUTPUT Capacity (VA)
6000
Capacity (Watts)
5400
On Battery Waveform
Pure Sine Wave
On Battery Voltage(s) (Vac)
200 ± 2%
208 ± 2%
220 ± 2%
230 ± 2%
240 ± 2%
Output Voltage Setting
Configurable
On Battery Frequency (Hz)
50 ± 0.5%
60 ± 0.5%
Output Frequency Setting
Configurable
Power Factor
0.9
ECO Mode Voltage Tolerance
± 10 %
± 15 %
Overload Protection
Internal Current Limiting , Circuit Breaker
Overload Protection (Line Mode)
105~125% Load for 1 min, 125~150% Load for 10 sec
Overload Protection (Battery Mode)
105~130% Load for 10 sec, 130~150% Load for 2 sec
Overload Protection (Bypass Mode)
Circuit Breaker
Crest Factor
3 : 1
Harmonic Distortion (Linear Load)
THD<3%
Harmonic Distortion (Non-linear Load)
THD<5%
Internal Bypass
Automatic Bypass , Manual Bypass
Maintenance Bypass
Yes
Outlet(s) - Total
11
Outlet Type
Hardwire Terminal Block x 1
IEC C19 x 2  
IEC C13 x 8  
Outlet(s) - Battery & Surge Protected
11
Outlet(s) - Critical Load (CL)
6
Outlet(s) - Non-Critical Load (NCL)
5
Typical Transfer Time (ms)
0
BATTERY Runtime at Half Load (min)
15
Runtime at Full Load (min)
5
Typical Recharge Time (Hours)
4
Start On Battery
Yes
Smart Battery Management (SBM)
Yes
User-replaceable
Yes
Hot-swappable
Yes
Battery Type
Sealed Lead-acid
Replacement Battery Pack
RBP0073
RBP Quantity (pcs)
2
Battery Quantity (Each RBP) (pcs)
10
Battery Voltage (Each RBP) (V)
120
Single Battery Capacity (AH)
12 V 7 AH
Extended Battery Module (EBM)
BPE240V30ART3U (Built-in Charger)
Max. EBM Quantity (pcs)
10
SURGE PROTECTION & FILTERING Surge Suppression (Joules)
2430
EMI/RFI Filtration
Yes
Phone/Network Protection RJ11/RJ45 (Combo)
1-in, 1-out
MANAGEMENT & COMMUNICATIONS LCD Panel
Yes
Detachable LCD Panel
Yes
LCD Information Display
Operation Type , Power Status , Battery Status , Load Status , Fault & Warning , Other Information , Event & Log
LCD Setting & Control
Mode Setting , Alarm Setting , Input & Output , Battery Setting , Fault & Warning , Communication , Event & Log , Security Setting , Language
LED Indicators
Power On , Line Mode , Battery Mode , Bypass Mode , Battery Capacity , Low Battery , Overload , UPS Fault , Wiring Fault , Replace Battery
HID Compliant USB Port(s)
1
Serial Port
Combo (RS232 + Dry Contact)
Dry Contact (with Relay)
Yes
Emergency Power Off (EPO) Port
Yes
Audible Alarms
Battery Mode , Low Battery , Overload , Overcharge , Overheat , UPS Fault , Replace Battery
Power Management Software
PowerPanel® Business Edition
SNMP / HTTP Remote Monitoring
Yes - with optional RMCARD205
 

PHYSICAL

Form Factor
Rack/Tower
Enclosure Construction
Metal
Color
Black
Rackmount Rail
Yes
Rackmount Ears
Yes

PHYSICAL SIZE - UPS MODULE

Dimensions (WxHxD) (in.)
17 x 10.4 x 32.3
Dimensions (WxHxD) (mm.)
433 x 264 x 820
Weight (lbs.)
230
Weight (kg.)
104.5
Installed Rack Height (U)
6

PHYSICAL SIZE - POWER MODULE

Dimensions (WxHxD) (in.)
17 x 5.2 x 32.3
Dimensions (WxHxD) (mm.)
433 x 132 x 820
Weight (lbs.)
62.7
Weight (kg.)
28.5
Installed Rack Height (U)
3

PHYSICAL SIZE - BATTERY MODULE

Dimensions (WxHxD) (in.)
17 x 5.2 x 26
Dimensions (WxHxD) (mm.)
433 x 132 x 660
Weight (lbs.)
167.2
Weight (kg.)
76
Installed Rack Height (U)
3

SHIPPING DIMENSIONS

Dimensions (WxHxD) (in.)
26 x 25.2 x 43.9
Dimensions (WxHxD) (mm.)
600 x 640 x 1115
Weight (lbs.)
288.2
Weight (kg.)
131

ENVIRONMENTAL

Operating Temperature (°F)
32 ~ 104
Operating Temperature (°C)
0 ~ 40
Operating Relative Humidity (Non-condensing) (%)
0 ~ 90
Operating Elevation (feet/meters)
0-10,000 feet (0-3,000 meters)
Storage Temperature (°F)
5 ~ 113
Storage Temperature (°C)
-15 ~ 45
Storage Relative Humidity (Non-condensing) (%)
0 ~ 95
Storage Elevation (feet/meters)
0-50,000 feet (0-15,000 meters)
Online Thermal Dissipation (BTU/hr)
1823
Audible Noise at 1.5M from Surface of Unit (dBA)
65

CERTIFICATIONS

Certifications
CE , C-Tick
RoHS
Yes

WARRANTY

Product Warranty Period (Year)2
Battery Warranty Period (Year)2
*Capacity (VA/Watts): 6000VA/5400W
*Typology: Online(Double Conversion)
*Form Factor:Rackmount/Tower (Convertible)
*Energy-Saving Tech: Yes
--Input:
*Volt Range:
120~139Vac for 0~25% Load
140~159Vac for 0~50% Load
160~179Vac for 0~75% Load
180~280Vac for 0~100% Load
*Frequency Range: 40~70 Hz
*Input Plug Type:(1) Hard Wire 3-wire
--Output:
*Volt Range:Pure Sinewave at 200,208,220,230,240Vac (Configurable)±2%
*Frequency Range: 50/60Hz(Auto-Sensing or Configurable) ±0.25Hz
*Transfer Time (Typical): 0ms
*Overload Protection:
Line Mode: 105~125% Load for1 min, 126~150% Load for 10 sec
Battery Mode: 105~130% for 10 sec, 131~150% load for 2 sec
*Short Circuit Protection:UPS Output Cut off Immediately or Input Fuse/Circuit Breaker Protection
*Surge Protection:Yes
*DSL/Phone/Fax/Modem protection: RJ11/RJ45(One In/One Out)
*Sealed Maintenance Free Lead Acid Battery:12V 7.2AHx 20
*Hot-Swappable:Yes
*Typical Recharge Time: 4 Hrs
*Half-load / Full-load (mins):15/5.1
*Indicators:Power On, Line Mode, Batt Mode, Bypass Mode, Fault, Replace Batt
*Audible Alarms: Batt Mode, Batt Low, Overload, UPS Fault, Replace Batt
*Multi-Function LCD Readout: Yes
*Self Test: Yes
*Auto-Charge/Auto-Restart: Yes
*Auto-Overload Recovery: Yes
*Cold Start(D): Yes
*This UPS is Hardwired and requires installation by a qualified electrician*