Cyberpower 1U Switched Auto Transfer Switch 10Amp Input/ Output- (Pdu15Swhviec12Atn)- Snmp Network

SKU
274258
Brand
Warranty
1 Year Manufacturer's return to base

No Longer Available

$0.00
Buy Now And Earn 0 Reward Points!

QUICK OVERVIEW

Connection - 12X Iec C13 Out - Iec 320 C14*2 In - 2 Yr Wty Pdu15Swhviec12Atnet

Product Overview


 

The CyberPower PDU15SWHVIEC12ATNET, a 12-outlet (rear), 1U rackmount switched automatic transfer switch (ATS) power distribution unit (PDU), provides 200-240V 15A output. It distributes unfiltered electrical pass-through to 12 IEC-320 C13 receptacles from redundant IEC-320 C14 plugs. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable.

The PDU15SWHVIEC12ATNET includes a SNMP/HTTP card (RMCARD203). With the SNMP card and an IP address on the network interface, users have real-time monitoring and outlet control of the PDU. The switched outlet receptacles can be managed individually or collectively. The LCD panel provides local monitoring of the PDU and on/off control for the outlets. It can also be used to measure the electrical current (displayed in amperes) used by connected equipment. The LCD panel also shows input and output voltages, active power consumption levels (displayed in kilowatts), and hardware and firmware versions.

Designed for datacenters and other demanding electrical applications, the PDU15SWHVIEC12ATNET has rugged, industrial-grade metal housing, a 10-foot AC power cord, and a cord retention tray. It can be mounted horizontally and is UL and CSA certified by ETL, and Class A FCC-certified. A three-year warranty covers the PDU and connected equipment for as long as you own the product.

 

  • Power Distribution
    Delivers AC power to servers, equipment, and connected devices via a power distribution unit.
  • Outlet Switching
    Output receptacles can be turned on, turned off, or recycled on demand or at programmed times to address a number of needs, including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads.
  • Automatic Transfer Switch
    Dual power cords (A & B) provide redundant power sources to devices with single power supplies and can be plugged into separate compatible sources* to ensure continuous access. Users select the preferred source as the primary input. CyberPower Smart App Online and Sinewave series UPS are highly recommended for use as the power source.
    *Note: Only sine wave AC power sources are compatible with this ATS PDU. Simulated sine wave AC power sources are NOT compatible.
  • LCD Panel
    Provides real-time meter status for current (amperes), input and output voltages, power consumptions (kilowatts), and hardware/firmware versions.
  • Upgradeable Hardware & LCD Firmware
    Are updatable to the latest versions by using the serial communication port and included cable.
  • Serial Communication Port & Cable
    Used to update/upgrade the hardware and LCD firmware.
  • Environmental Sensor Option
    Supports optional environment sensor (ENVIROSENSOR).
  • SNMP/HTTP Card
    Included and installed, RMCARD203 provides outlet control, remote monitoring, reporting, and event notifications, via Email, SMS Text, or SNMP Trap. RMCARD203 firmware is upgradeable with FTP process.
  • Protocol Support
    This Switched ATS PDU provides protocol support for PowerPanel Business Edition, HTTP, TCP/IP, UDP, DHCP, and SNMP including SNMPv3, and IPv4, IPv6, NTP, SMTP protocols.
  • Administrative Rights
    Administrator and user rights can be established to provide IT personnel with access to the Management Console via a web browser to monitor and/or manage the PDU settings.
  • Switchless Design
    Designed without a power switch and circuit breaker (on most models) to prevent accidental power interruptions.
  • Network-Grade Plugs and Outlets
    Highly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.
  • Rackmounting Brackets
    Allow for 1U horizontal rack installation.
  • Cord Retention Brackets
    Secures power cords, keeping them organized and accessible. Helps cords stay plugged in.
  • Three-Year Limited Warranty
    Covers the PDU for three years and connected equipment for as long as you own the product. See warranty for details.
What’s In The Box

ATS PDU, 2 Mounting Brackets, 24 M4x8 Bracket Mounting Screws, 6 M5x12 Rack Mounting Screws, 6 Washers, Cord Retention Tray, 2 M3x4 Cord Retention Tray Mounting Screws, 21 Cable Ties, RJ45/DB9 Serial Port Connection Cable, Jumper, User Manual, Registration Card, CD, 3 IEC Socket Power Cord Stands, 22 M3x4 Screws, Power Cord 10 feet IEC-320 C13/C14 x 2, 21 Power Cord Retention Cable Clips, 21 Cable Ties (IEC Type ATS)

Input  
Nominal Input Voltage 200 – 240 VAC
Frequency 50/60 Hz
Maximum Current 15A (derated to 12A)
On/Off Switch No
Plug Type 2 x IEC-320 C14
Plug Style Straight (Socket)
Cord Length 10 ft
Output  
Nominal Output Voltage 200 – 240 VAC
Outlet Banks 1
Outlets – Total 12
Outlets – Front 0
Outlets – Rear 12
Outlet Type IEC-320 C13
LCD Readout KW
Voltage
Amperage
Network Information
HW/FW Version
LED Indicators Input
Output Load
Tx/Rx
LINK
Outlets
Communication  
SNMP / HTTP Remote Monitoring RMCARD203 (Installed)
RMCARD205 (sold separately)
Protocols TCP/IP
UDP
DHCP
SNMP
HTTP
Connectivity Network
Environmental Sensor
Serial
Physical  
Dimensions – H×W×D (in) 17.05 x 1.75 x 9.30 inches
Rack Size 1U
Weight (lbs) 8.82 lbs
Style Rackmount
Form Factors Supported 1U rackmount
Cord Retention Tray/Cord Organizers Yes
Adjustable Mounting Brackets 1 set (L-long)
External Site Ground Pin Yes
Environmental  
Operating Temperature 32 – 113 °F (0 – 45°C)
Operating Humidity 0 – 95% (non-condensing)
Maximum Operating Elevation 13,100 ft (4,000 m)
Storage Temperature 5 – 113 °F (-15 – 45°C)
Maximum Storage Elevation 50,000 ft (15,000 m)
Thermal Dissipation 41 BTU/hr
Certifications  
Safety UL60950_1 certified by ETL
CSA C22.2
FCC Class A
Environmental RoHS Compliant
Warranty  
Product Warranty 3 year
GENERALType: Switched Phase: Single PhaseINPUTNominal Input voltage (Vac): 200 ~ 240Input Frequency (Hz): 50/60Maximum Input Current (A): 10Input Connector Type: IEC C14x 2Power Cord Length (ft.): 10Power Cord Length (m.): 3.05OUTPUTOutput Voltage (V): Depends on InputOutlet(s) - # of Bank(s) (Bank): 1Outlet(s) – Total: 12Outlet(s) – Front: 12Outlet Type: IEC C13 x 12Remote Individual Outlet Control: YesTypical Transfer Time (ms): 8 ~ 12PHYSICALInstalled Rack Height (U): 1Form Factor: 1U Horizontal Rackmount Enclosure Construction: SteelColor: BlackCord Retention Tray: YesIEC Receptacle Locking: YesExternal Site Ground Pin: YesAdjustable Mounting Brackets: 1 set PHYSICAL SIZEDimensions (WxHxD) (in.): 17.05 x 1.75 x 9.3Unit Dimensions (WxHxD) (mm): 433 x 44 x 236Net Weight (Ibs.): 8.8Net Weight (kg): 4