Apc Smart-ups Rt 1000va 230v, Online 1000va/ 700w, Input 220, 230, 240v/ Output 230v
No Longer Available
QUICK OVERVIEW
OUTPUT POWER CAPACITY: 1,000VA,700W, MAX CONFIGURABLE POWER: 1000VA, 700W
NOMINAL OUTPUT VOLTAGE: 230 V
OUTPUT VOLTAGE NOTE: CONFIGURABLE FOR 220: 230 OR 240 NOMINAL O/P VOLTAGE
OUTPUT CONNECTIONS: (6) IEC 320 C13, (2) IEC Jumpers
NOMINAL INPUT VOLTAGE: 230 V
INPUT FREQUENCY: 50/60 Hz +/- 3 Hz (auto sensing)
INPUT CONNECTION TYPE: IEC-320 C14
INPUT VOLTAGE RANGE FOR MAIN OPERATIONS: 160-280V, 100-280V (Adustable)
RUNTIME: TYPICAL BACKUP TIME: AT HALF LOAD: 24.4 min (350 Watts)
AT FULL LOAD: 10.2 minutes (700 Watts)
BATTERY TYPE: Maintenance-free sealed Lead-Acid battery with suspended
electrolyte: leakproof
COLOUR: Black, DIMENSIONS:(H X W X D)(cm) 8.51 x 43.18 x 48.26, WEIGHT: 23k
INTERFACE PORT: DB-9 RS-232, SmartSlot
AVAILABLE SMART SLOT INTERFACE QUANTITY: 1
INCLUDED SOFTWARE: APC PowerChute Business Edition 5 Node
FEATURES: Audible Alarms, Automatic Self Test, Automatic Shutdown,
Built-in automatic bypass, Cold-start, Double Conversion On-Line,
Downloadable Firmware, Faster Recharge Time, Input Power Factor
Early-warning Problem Notification, Generator Compatible, Correction,
Intelligent Battery Management, Lightning and Surge Protection, Load Meter,
Multiple O/P Voltages, NW-grade line conditioning, Scalable Run Time,
Overload Handling Capacity, Programmable Frequency, Rack Mount
Sine-wave output, Status Indicator LED`s, Surge Protection
All APC products have a 2 year advance replacement
warranty
PI Date | Jun 2010 |
Brand Name | APC |
Manufacturer Web Site | http://www.apc.com |
Product Line | Smart-UPS |
Product Model | Not defined |
Type | Sealed Lead Acid |
Input Voltage | 230Volt |
Output Power | 700Watt |
Output Voltage | 230Volt |
Surge Energy Rating | 420Joules |
Depth (mm) | 483.0 |
Height (mm) | 432.0 |
Width (mm) | 85.0 |
Weight (Kg) | 23.0 |
Colour | Black |
Other Features | * Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault * Scalable runtime Allows additional run time to be quickly added as needed * Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging * Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced * Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS |