CISCO PHYSICAL ACCESS READER MODULE EN CIAC-GW-RDR
No Longer Available
Features
Table 1 describes the features of the Cisco Physical Access Reader Module.
Table 1. Cisco Physical Access Reader Module Features
Feature Description
Doors Managed Up to two doors.
Reader/Lock Power Powers external devices such as readers or locks. The maximum
current draw is limited to 650mA at
12 VDC.
Connectors
Table 2 describes the connectivity and connectors of the Cisco Physical Access
Reader Module.
Table 2. Cisco Physical Access Reader Module Connectors
Connector Description
Weigand Reader There is one 10-pin Weigand/clock and data reader interface on
the device. This can be configured as
two 5-pin Weigand/clock and data interfaces for installations where a 5-pin
interface is sufficient.
Inputs There are three inputs, each of which can be configured as supervised or
unsupervised.
Outputs There are three Form C relay outputs, with contacts rated 5A @ 30V DC or
125VAC (resistive). Each
can be configured as either Normally Closed (NC) or Normally Open (NO)
Connector Description
Tamper Input Unsupervised input; raises a ?tamper? alarm when activated. Can be
repurposed for general use by
software configuration.
Power Fail Input Unsupervised input; raises a ?power fail? alarm when activated.
Can be repurposed for general use by
software configuration.
Power Includes a 2-pin connector for connecting a 12 to 24 VDC external power
source.
RS-485 The RS-485 interface is reserved for future use.
CAN Bus A 3-wire connection is used to connect to the controller area network
(CAN) bus.
CAN Termination A switch allows for the CAN bus to be terminated. This is needed
for the last module on the CAN bus.
Specifications
Table 3 provides specifications of the Cisco Physical Access Reader Module.
Table 3. Cisco Physical Access Reader Module Mechanical Specifications
Item Description
Housing Aluminum
Dimensions (LxWxH) ? 5 x 7 x 2.14 in.
? 127 x 178 x 54.6 mm
Without Plugs and
Brackets
With Plugs With Brackets With Plugs and
Brackets
Weight
1.52 lb (688 g) 1.67 lb ( 756 g) 1.69 lb ( 761 g) 1.84 lb ( 830 g)
Certifications ? FCC
? UL
? CE
perating Temperature ? Indoors only
? 32 to 122?F (0 to 50?C)
Humidity 5 to 95% relative, non-condensing
Power 12 to 24 VDC (+/- 10%) through an external power supply
Marketing Text | The Cisco Physical Access Reader Module can connect to a maximum of two doors and associated inputs and outputs. |
PI Date | Aug 2012 |
Brand Name | Cisco |
Manufacturer Web Site | http://www.cisco.com/ |
Product Type | Reader Module |
Depth (mm) | 127.0 |
Height (mm) | 54.6 |
Width (mm) | 178.0 |
Operating Temperature | 0 to 50°C |
Compatibility | * Cisco Physical Access Gateway |
Other Features | * Up to two doors * Reader/Lock Power * There is one 10-pin Weigand/clock and data reader interface on the device * There are three inputs, each of which can be configured as supervised or unsupervised * There are three Form C relay outputs, with contacts rated 5A @ 30V DC or 125VAC (resistive) * Tamper Input: Unsupervised input; raises a "tamper" alarm when activated. Can be repurposed for general use by software configuration * Power Fail Input: Unsupervised input; raises a "power fail" alarm when activated. Can be repurposed for general use by software configuration * CAN Termination: A switch allows for the CAN bus to be terminated |