Cyberpower- Switched Epdu (pdu30swvhvt24fnet) - 2 Years Advanced Replacement Warranty Pdu30swvhvt24fnet
Product Overview
The CyberPower PDU30SWVHVT24FNET, a 24-outlet (front), 0U rack mount switched power distribution unit (PDU), provides 200-240V 30A output. It distributes power to IEC-320 (21-C13 and 3-C19) receptacles from a single NEMA L6-30P plug with unfiltered electrical pass-through. The switched outlet receptacles can be managed individually or collectively over the network using CyberPower Management Console/web browser and the RJ45 Ethernet port for network connection or locally using the LCD controls.
Outlets can be turned on, turned off, or recycled on demand or at programmed times to address a number of needs including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads. The PDU30SWVHVT24FNET comes with a three-year limited warranty that covers defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date.
- Power Distribution
Delivers AC power to servers, equipment, and connected devices via a power distribution unit. - Switch-Free Design
Safeguards against accidental power shutdown. - Switchable Outlets
Provides local and remote control for individual and multiple outlets. Local control: turn on/turn off outlets and disable unused outlets. Remote control: restart outlets and devices, turn on/turn off, schedule power on/off sequencing, and disable unused outlets. - CyberPower Management Console
A hardware interface built into Monitored and Switched PDUs. Its functionality includes the ability to switch PDU outlets on and off, reboot connected equipment locally or remotely, schedule power cycling of attached equipment, and perform other tasks, such as load monitoring and event logging. - Remote and Local Monitoring
Enables offsite and onsite tracking of PDU vitals; provides outlet control for individual and networked clients. - Automatic Event Notifications
Provide immediate updates about power events via email, SMS text, or SNMP traps. - Upgradeable Firmware
Downloadable improvements (firmware updates) to programs that run the PDU. - Digital Display
Provides easy-to-read information about amperage, voltage, KW, IP address, and other PDU information. - Network-Grade Plugs and Outlets
Highly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices. - Long Input Power Cord
Reaches distant power sources, allowing the PDU to be placed where it’s needed. - Twist Lock Plug
Secures an outlet by twisting and locking into place to prevent accidental disconnection. - Cord Retention Tray
Secures power cords, keeping them organized and accessible. Helps cords stay plugged in. - Configurable Mounting Brackets
Allow for installation of the PDU in the following configurations: 0U (vertical, under counter, and wall mount), 1U (horizontal, vertical, under counter, and wall mount), and 2U (horizontal and wall mount). - Durable Metal Housing
Protects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product. - Three-Year Limited Warranty
Covers defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date. See warranty for details.
What’s In The Box
PDU, 2 Mounting Brackets, 6 Flat Head M4x4 Bracket Mounting Screws, 3 Cord Retention Tray, 30 Cable Ties, 14 M3x6 Cord Retention Tray Mounting Screws, 6 M5x12 Screws, 6 Washers, RJ45/DB9 Serial Port Connection Cable, User Manual, Registration Card, CD, 2 Keyhole Mounting Pegs, 4 M4x5 Screws, 12 M3x4 Screws, 36 Power Cord Retention Cable Clips, 36 Cable Ties

Understanding PDUs
Power Distribution Units (PDUs) by CyberPower are engineered to distribute reliable network power to multiple devices. A PDU does not generate conditioned power, but delivers AC power from a UPS (uninterruptible power supply), a generator, or utility power source to servers, network/telecom equipment, and other devices. Selecting the best PDU for your needs depends on the output voltage required, the number of outlets needed for connected devices, plug and outlet types, and mounting options.
Versatile. CyberPower PDUs are designed with as many as 38 outlets. Offered in 0U, 1U, and 2U form factors, each PDU includes the necessary hardware to be mounted vertically or horizontally inside densely configured rack enclosures. The PDU can also be mounted on a wall or under a shelf.
Scalable. In smaller networks, conditioned power can be distributed through a single PDU from a UPS, while a complex data center might require the connection of multiple PDUs to a large-capacity UPS system.

Different PDU Series for Different Needs
CyberPower offers multiple offerings of power distribution units (PDUs): Basic, Metered, Metered ATS, Monitored, Switched, Switched ATS and Maintenance-Bypass. Each series serves a specialized purpose. Models within the same series have similar features and capabilities.
Basic: Reliable and unfiltered AC power distribution from a UPS system, generator, and/or utility source to multiple connected devices.
Metered: Network-grade power distribution plus load meters (amps) to prevent overloads and safely optimize load levels.
Monitored: Network-grade power distribution with remote monitoring through an SNMP network interface and local management via a digital meter display to prevent downtime due to overloads or other power events.
Switched: Intelligent, network-grade power distribution and the ability to control outlets individually or collectively to solve power issues such as shutdowns or to plan scheduled rebooting. A digital meter provides information on load and voltage, as well as local control of the outlets. An SNMP connection enables remote monitoring and control of the outlets to ensure complete control regardless of location.
Switched Metered-by-Outlet: Monitor the power consumption of individual outlets in real-time over the network, or locally using the PDU’s interactive digital display. Outlets can be switched on and off remotely for unscheduled reboots, automated load shedding, controlled power-cycling and more.
Metered ATS: Redundant NEMA plugs. Dual power cords can be plugged into separate power sources. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation.
Switched ATS: Individual management of switched outlet receptacles. Remote and local control of outlets. Redundant NEMA plugs. Dual power cords can be plugged into separate power sources. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation.
Maintenance-Bypass: Maintenance Bypass PDUs allow the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of connected equipment when performing maintenance, replacing batteries, or installing a new UPS.

Power Device Network Utility
The Power Device Network Utility gives users an easy-to-use interface for establishing the IP addresses of CyberPower PDU devices, RM Cards, and PowerPanel Business Edition Agents and Clients. It scans network devices with MAC addresses that match CyberPower network hardware. Once found, the device(s) can then be configured with a specific IP address, subnet mask, and gateway address, allowing the device(s) to work properly on the network and to integrate with the CyberPower Management Console.

CyberPower Management Console
The CyberPower Management Console is a Network Management System (NMS) that provides real-time remote power monitoring and control of Power Distribution Units (PDUs). This useful hardware interface is built into CyberPower Switched and Monitored PDUs. For both Switched and Monitored PDUs, the Management Console enables administrators to perform operational tasks, such as load monitoring and event logging via email, text, or SNMP trap notifications. With a Switched PDU, it enables manual power cycling to restart unresponsive devices and allows for scheduled power cycling of outlets and/or load shedding for specific devices connected to the PDU..
Input | |
---|---|
Voltage | 200 – 240 V |
Maximum Current | 30A (derated to 24A) |
Frequency | 50/60 Hz |
Plug Type | NEMA L6-30P |
Plug Style | Straight, Twist Lock |
Cord Length | 10 ft |
Output | |
Nominal Output Voltage | 200 – 240 V |
Outlet Type | IEC-320 C13 (21) / C19 (3) |
Outlets – Front | 24 |
Outlets – Rear | 0 |
Outlets – Total | 24 |
Meter Readout | KW Voltage Amperage IP Address |
Overload Protection | 30A (derated 24A) |
Overload Protection (Each Bank) | 15A |
Outlet Banks | 2 |
LED Indicators | Load Tx/Rx LINK Outlets |
Management & Communications | |
SNMP / HTTP Remote Monitoring | TCP/IP UDP DHCP SNMP HTTP |
Connectivity | RJ45 DB9/RS232 |
Physical | |
Rack Size | 0U |
Form Factors Supported | Vertical or horizontal mounting supported in wallmount applications racks and a variety of other surface types |
Style | Vertical Rackmount Wallmount |
Cord Retention Tray/Cord Organizers | Yes |
External Site Ground Pin | Yes |
Adjustable Mounting Brackets | 1 set |
Dimensions – W×H×D (in) | 2.20 x 70.0 x 1.75 inches |
Weight (lbs) | 15.20 lbs |
Environmental | |
Operating Temperature | 32 – 113 °F (0 – 45 °C) |
Operating Humidity | 0 – 95% (non-condensing) |
Storage Temperature | 5 – 113 °F (-15 – 45 °C) |
Maximum Operating Elevation | 14,760 ft (4,500 m) |
Maximum Storage Elevation | 50,000 ft (15,000 m) |
Certifications | |
Safety | UL60950_1 certified by ETL CSA C22.2 FCC Class A |
Environmental | RoHS Compliant |