General | |||||||||||
Topology | On-line double conversion with PFC (Power Factor Correction) system | ||||||||||
Configuration | Rack/Tower | ||||||||||
Part Number | 9PX5Ki | ||||||||||
Rating (VA/Watts) | 5000/4500 | ||||||||||
Dimensions (H x W x D, mm) | 130 (3U) x 440 x 685 | ||||||||||
Weight (kg) | 48 | ||||||||||
Warranty | 3 years on electronics, 2 years on battery | ||||||||||
Electrical Input | |||||||||||
Connection | Hardwired - see manual for terminal block layout ![]() | ||||||||||
Input Voltage Range | 176-276V without derating (up to 100–276V with derating) | ||||||||||
Nominal Voltage | 200/208/220/230/240V | ||||||||||
Frequency | 50/60 Hz autoselection | ||||||||||
Frequency Range | 40-70 Hz | ||||||||||
Short Circuit Current | 90 A | ||||||||||
THDI | <5% | ||||||||||
Electrical Output | |||||||||||
Voltages | 200/208/220/230/240V +/– 1% | ||||||||||
Voltage THD | < 2% | ||||||||||
Output Receptacles | Hardwired - see manual for terminal block layout ![]() (8) IEC-320-C13 ![]() (2) IEC-320-C19 ![]() | ||||||||||
Overload Capacity | 102–110% : 120s, 110–125%: 60s, 125–150%: 10s, >150%: 500ms | ||||||||||
Efficiency (Normal Mode) | Up to 94% in Online mode, 98% in Hi-Efficiency mode | ||||||||||
Output Frequency | 50/60 Hz autoselect, frequency converter as standard | ||||||||||
Load Crest Factor | 3:1 | ||||||||||
Battery | |||||||||||
Runtime (Minutes) 500 1000 1500 2000 2500 3000 3500 4000 4500 0 100 200 300 400 500 600 700 800 900 1000
Load (Watts) Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc. Actual runtime may vary from +/- 15% around these typical values Show: Hover over graph for detailed runtime values | |||||||||||
Battery Management | ABM® and Temperature compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of external battery units. | ||||||||||
Extended Battery Capability | EBM (3U) | ||||||||||
Communications | |||||||||||
User Interface | Multilingual graphical LCD display | ||||||||||
Communication Ports | 1 USB port, 1 RS232 serial port (USB and RS232 ports cannot be used simultaneously), 4 dry contacts (DB9), 1 mini terminal block for remote On/Off and 1 for remote power Off, 1 DB15 for parallel operation | ||||||||||
Communication Slot | 1 slot for Network-MS card, ModBus-MS or Relay-MS cards. | ||||||||||
Environmental & Standards | |||||||||||
Audible Noise | <45dB | ||||||||||
Operating Temperature | 0 to 40°C continuous | ||||||||||
Safety markings | IEC/EN 62040-1, UL 1778, CSA 22.2 | ||||||||||
EMC Markings | IEC/EN 62040 -2 , FCC Class A, IEC/EN 62040-3 (Performance) | ||||||||||
Approvals | CE, CB report (TUV), UL |